Call Us :- +919818350088
countronindia@gmail.com

Conductivity Indicators Controllers

Our firm is occupied in providing a huge range of Conductivity Indicators Controllers. These are used to measure either solution conductivity. These controllers are one of the most common environmental tests of aquatic samples. Apart from these series, easily procured in various configurations to meet the current needs of consumers. Conductivity Indicators Controllers are an automated device to control external devices. These are convenient to place at a fixed distance under the assistance of talented professionals. These are suitable in chemicals, pharma, water and other industries.

2 Set-Point Digital Conductivity Controller

We are providing a unique arrangement of 2 Set-Point Digital Conductivity Controller. It is designed for fast and accurate measurement. This controller is able to allows us to measure the level of conductivity in solutions. 2 Set-Point Digital Conductivity Controller helps to pass an electric current. Furthermore, provided controller is an external devices based on the measured conductivity value. It is an automated device which ensures an internal alarm set discourages unauthorized adjustments

 

 

 

 

Specification

Display

3 Digit LCD

Range

a. 199.9s
b. 1999s
c. 19.99ms
d. 199.9ms
The range is selectable from the rear and can be calibrated by Cell Adj at the front for individual range.

Resolution

0.1s to 0.1ms depending on range selected.

Accuracy

0.5% of Full Scale 1 Least Significant Digit.

Sensor

Contact Type with Cell Constant 1.0

Temperature

Uses PT100, precision temperature sensor (External).

Compensation

The Compensation is internally set at 2% per C
NOTE: If PT100 is not available, then fix a simulated resistance of PT100 @ 25C approx. 110. Instrument will not work otherwise.

Limit Setting

Using 2 Nos. 10 turn precision trimpots on front panel to set the High/Low Limi

Control Output

Two set of NO-P-NC, 5 Amps potential free Relay Contacts.
a. Relay 1 (High) ON, for Conductivity > High Limit
b. Relay 2 (Low) ON, for Conductivity < Low Limit

Recorder Output

0-2V for the selected range
Max. current output capability 2mA

Supply

110V AC/220V AC 15% Internally selectable

Size

Front Fascia 96mm x 96mm, Cut Out 92mm x 92mm

Cabinet

Flame retardant grade Plastic enclosure

Digital Conductivity cum TDS Indicator

 

  • Model code:5500
  • Product Name:Digital Conductivity cum TDS Indicator
  • Category:conductivity_meters_controllers
  • Sub Category:conductivity_indicators 

Specification

Display

3 Digit 13mm High, RED LED.

Cell Factor

1.0 & 0.1 Selectable.

Conductivity Range

A)For Cell Factor 1.0
1) 199.9 mS/cm
2) 19.99 mS/cm
3) 19999 mS/cm
4) 199.9 mS/cm
: B)For Cell Factor 0.1
1) 19.99 mS/cm
2) 19999 mS/cm
3) 199.9 mS/cm
4) 19.99 mS/cm

TDS Range

2000 ppm

Temperature Compensation

Automatic Using External PT-100 Sensor..

Display

3 Digit 13mm High, RED LED.

Cell Factor

1.0 & 0.1 Selectable.

Conductivity Range

A)For Cell Factor 1.0
1) 199.9 mS/cm
2) 19.99 mS/cm
3) 19999 mS/cm
4) 199.9 mS/cm
: B)For Cell Factor 0.1
1) 19.99 mS/cm
2) 19999 mS/cm
3) 199.9 mS/cm
4) 19.99 mS/cm

TDS Range

2000 ppm

Temperature Compensation

Automatic Using External PT-100 Sensor..

Conductivity TDS pH ORP Indicator

Backed by a cutting edge technology, we have become a promising manufacturer and trader of a wide gamut of Conductivity TDS pH ORP Indicator. Our offered indicator is precisely fabricated by our experienced experts by making use of technologically advanced machines and equipments at our production unit.  Also, it is in compliance with all the set quality guidelines of the industry. Our range of Conductivity TDS pH ORP Indicator is best known for features like accurate dimensions, strong structure, corrosion resistance, and so on.

 

  • Model code:5501
  • Product Name: Conductivity TDS pH ORP Indicator
  • Category: conductivity_ meters_ controllers
  • Sub Category: conductivity_ indicators

 

Features

 

  • Accurate pH display with 0.01pH resolution
  • Auto buffer recognition with 2 point calibration for pH
  • Auto/Manual temperature compensation selectable for both pH and Conductivity
  • 4 Step Range selection 0.1s to 199.9ms for conductivity
  • Cell Factor selectable for both 1.0 and 0.1
  • Digital calibration for conductivity
  • Auto Temp Compensation using PT100 sensor
  • One touch switching between conductivity and pH display selections
  • Large alphanumeric LCD display with bright back light
  • Aesthetically designed front panel with membrane switches and sleek bench top cabinet
Specification

 

Display

2 line large alphanumeric display with back light illumination

Ranges

pH: 0.00 to 14.00 pH
ORP: 0-2000mV
Conductivity: 19.99ms/1999s/199.9s/19.99s in 0.1 Cell Constant
199.9ms/19.99ms/1999s/199.9s in 1.0 Cell Constant
TDS: 0-1999ppm

Resolution

pH: 0.01pH
ORP: 1mV
Conductivity: 0.01ms or 0.01s depending on range & Cell factor
TDS: 1ppm

Auto Temp. Comp.

0-100C using PT100 external sensor for pH and Conductivity

Manual Temp. Comp.

Settable from front panel from 0-100.0C for pH and Conductivity

pH Calibration

2 Point calibration with auto buffer recognition.
Buffers recognized: 4.00, 7.00, 9.00, 10.00 pH

Conductivity Calibration

Digital calibration by factor multiplication from 0.75-1.25

Accuracy

0.5% 1 Digit

Supply

220V AC 10% @ 50Hz

Enclosure

Plastic (ABS). Size 272x192x90mm

Weight

900gms

Conductivity Transmitter

We are a leading manufacturer and trader of a wide gamut of Conductivity Transmitter.  Used for various industrial applications, our range of transmitter is manufactured by making use of high grade basic materials which are sourced from reliable vendors of the industry.  Our range of Conductivity Transmitter is best known for its aesthetically designed weather-proof cabin.  Also, we have made it available for clients in different range starting from 19.99 s  to 199.9mS (Factory Set). Also, these are timely delivered to clients end in a timely manner.

  • Model code:1004
  • Product Name: Conductivity Transmitter
  • Category: conductivity _meters _controllers
  • Sub Category: conductivity_ indicators

Features

  •  Precision indication of conductivity in 4-20mA output
  • Automatic Temperature Compensation @2%/C using PT-100
  • Range can be provided from 19.99 s  to 199.9mS (Factory Set)
  • Aesthetically designed weather-proof cabin

Specification

Range

19.99ms 199.9ms

(Factory Set)

1999 s 19.99ms
199.9s 1999 s
19.99s 199.9s
(0.1Cell) (1.0 Cell)

Accuracy

0.5% of F.S. 1 LSD

Sensor

Contact type with Cell constant 0.1 or 1.0.

Temp.

Uses PT-100, precision temperature Comp.
sensor (external). The compensation is
internally set at 2%/C

Supply

220V AC 15% @ 50Hz/60Hz

Size

198mm x 89mm x 60mm (LxWxH) with flange

X


Back to top