Call Us :- 08071930600
countronindia@gmail.com
Ampere Hour Meter with dual time relays

Ampere Hour Meter with dual time relays

Product Details:

  • Resistant Feature Resistant to dust, humidity, and mild chemicals
  • Batteries Type Compatible with lead-acid and lithium batteries
  • Accuracy 1% of full scale
  • Pressure Atmospheric pressure range
  • Usage & Applications Battery charging, energy monitoring, industrial automation
  • Product Type Ampere Hour Meter with Dual Time Relays
  • Material ABS plastic housing
  • Click to View more
X

Ampere Hour Meter with dual time relays Price And Quantity

  • Flush panel mount
  • 1A to 10A DC
  • Non-volatile memory for ampere hour data
  • Dual programmable time relays
  • Rated 5A @ 230V AC
  • 7-segment digital LED display
  • Audio/visual overcurrent and undervoltage alarms
  • Panel buttons with tactile feedback

Ampere Hour Meter with dual time relays Product Specifications

  • -10C to 55C
  • Ampere Hour Meter with Dual Time Relays
  • ABS plastic housing
  • 1% of full scale
  • Battery charging, energy monitoring, industrial automation
  • 5V to 240V DC
  • Atmospheric pressure range
  • Black and grey
  • Overload and short circuit protection included
  • Approx. 350 grams
  • 120mm x 96mm x 65mm
  • High grade, flame-retardant ABS enclosure
  • Compatible with lead-acid and lithium batteries
  • Resistant to dust, humidity, and mild chemicals
  • Standard panel mount
  • 50 to 60 Hz
  • Flush panel mount
  • 1A to 10A DC
  • Non-volatile memory for ampere hour data
  • Dual programmable time relays
  • Rated 5A @ 230V AC
  • 7-segment digital LED display
  • Audio/visual overcurrent and undervoltage alarms
  • Panel buttons with tactile feedback

Product Description

  • Model code:804AH
  • Product Name:Ampere Hour Meter with dual time relays
  • Category:ampere_hour_meters
  • Sub Category:electroplating_applications

Specification

Display

4 Digit 7 Segment Red LED display for Instantaneous Current
6 Digit 7 Segment Red LED display for Ampere-Hours/Mins
2 Red LEDs to indicate status of the 2 Relay contacts

Max. Shunt

Maximum 9999 Amps corresponding to 75mV settable

Calibration

from front panel

Set Point

Settable from 0-999999

Resolution

1AH/0.1AH/1AM/0.1AM

Totaliser

6 Digits for Ampere-Hour or Ampere-Minutes

Time Relays

2 relay contacts with individual time settings in Mins:Secs for timed dual dosing after the Ampere-Hour limit is reached

Contact Rating

NO-P-NC @ 5Amps/220V AC

Memory

Settings and Ampere-Hours saved in solid state EEPROM

Lock

Non-volatile EEPROM solid state memory
Stores programmed value of shunt, preset value, current Amp-Hr and the current
Cumulative Amp-Hr to preserve current status on power failure

Lock

By rear jumper to prevent accidental tampering with settings

Supply

220V AC @10% @ 50/60Hz
220V AC ± 10% at 50/60Hz
Front Fascia 96mm x 99mm

Size

Depth 135mm.
Cut Out : 91mm x 91mm

Weight

800 grams



Advanced Monitoring and Accurate Measurement

This meter seamlessly tracks ampere hour consumption, delivering precise readings with 1% accuracy across a broad voltage and current range. Its dual programmable relays allow flexible time-based controls, making it suitable for a variety of industrial and battery management applications.


Reliable Design for Industrial Applications

Encased in a high-grade, flame-retardant ABS box, the device resists dust, humidity, and mild chemicals. Overload and short circuit protection, along with robust audio and visual alarms, enhance operational safety, supporting installations in challenging industrial settings.


Intuitive Control and User-friendly Display

The flush panel mount and tactile panel buttons provide straightforward control directly from the unit. A clear 7-segment digital LED display ensures at-a-glance monitoring, while the non-volatile memory securely stores data even during power interruptions.

FAQs of Ampere Hour Meter with dual time relays:


Q: How does the Ampere Hour Meter maintain data integrity during power loss?

A: The device uses non-volatile memory for ampere hour data storage, ensuring all measurements are securely retained even in the event of a power interruption.

Q: What are the key benefits of dual programmable time relays in this meter?

A: Dual programmable time relays offer flexible control for automating processes, enabling precise scheduling of charging or monitoring tasks, which enhances efficiency in battery management and industrial automation.

Q: Where can this Ampere Hour Meter be installed?

A: Designed for flush panel mounting, the meter fits standard panel cutouts and is suitable for industrial control panels, battery charging stations, and energy management systems.

Q: What type of alarms does the unit provide for abnormal conditions?

A: The meter features both audio and visual alarms to alert users in case of overcurrent or undervoltage situations, providing immediate feedback for quick corrective action.

Q: When is this meter most useful for battery-based applications?

A: It is particularly valuable during battery charging and monitoring cycles, ensuring safe and efficient charging for lead-acid or lithium batteries by keeping track of ampere hours and protecting from overcurrent scenarios.

Q: How is the Ampere Hour Meter controlled or programmed?

A: All settings and programming are accessed through panel buttons with tactile feedback, providing straightforward, intuitive operation directly on the front panel.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Ampere Hour Meters' category